Description
The TOMY Multiple Shared Use Autoclaves SX-700 / 500 / 300 are designed to meet the sterilization needs for a wide variety of sizes and shapes of articles to be sterilized especially in the washing room or central autoclave room arranged for shared use among a few or several laboratories.
User Friendly and Safety Features
Ergonomic Height Design
Easy operation using the “Top-open lid”
The SX series Autoclaves are designed to be the perfect height to easily load and unload articles into the chamber.
A top-open lid, which can be operated easily with a single hand and a single foot, is provided. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.
Space-saving
The SX series Autoclaves have a small footprint and allow for flexibility in installation locations. In a comparison of 50L-class models, the SX-500 has a smaller installation space*1 than our previous model. You can use your laboratory more efficiently and maximize floor space.
Checking the Loading Capacity
Autoclaves are used by various operators in a variety of places, including individual laboratories as well as shared washing rooms, central equipment rooms and so on. And sterilization applications also vary widely for preparation of glassware, preparation of media and distilled water, and decontamination of waste material like petri dishes, etc. Knowing how many articles you want to sterilize can be accommodated will make it easier to plan for sterilization. In the SX-700 as an example, a basket ACA-700B can be loaded with 500ml x 11 bottles or 500ml x 7 flasks, etc.
Intuitive Display
The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.
Sterilizing course selection
The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for
normal sterilization.
Attentive Liquid Sterilization Course
When autoclaving liquid samples, opening the lid while the liquid temperature is high may cause a sudden boiling. It is necessary to allow the pressure and temperature to drop naturally without forced exhaust after sterilization.
The SX series Autoclaves have a LIQUID course that automatically sterilizes like this process with a single operation. It reduces spillage of media or solvent inside the chamber and supports smooth shared use in your facilities.
Printer supporting to keep Sterilization Log
High Altitude Sterilization Program*1
Autoclave operates by generating steam under pressure and temperature. Therefore, its sterilization process can be greatly affected by the atmospheric pressure at the location where the autoclave is installed.
The SX series Autoclaves allow users to operate even though at high altitude place*2.
Operating temperature range will be changed after installed the high altitude program.
More Secure Sterilization considering Heat Transfer Time Lag
There is Heat Transfer Time Lag when using the steam autoclave. The display shows the ambient temperature inside the chamber, but the temperature of articles to be sterilized arrives later than the display temperature. This is called “Heat Transfer Time Lag“.
For more secure sterilization, it is recommended to add the Heat Transfer Time Lag to the sterilization time.
Automatic timer countdown by sample temperature w / External Temperature Sensor
The SX series Autoclaves can check the temperature of articles to be sterilized with an optional External Temperature Sensor. The detected temperature by the External Temperature Sensor can be used to count down the sterilization time (e.g. 20 min.) . That means sterilization will be done with the temperature of articles inside the chamber automatically without calculating Heat Transfer Time Lag manually by yourself.
The detected temperature also works to open the lid safely after sterilization. The lid can be opened after the temperature of articles drops down* and it prevents the sudden boiling of liquid sample.
These features help you to save your time to decide the sterilization time and to reduce troubles of spillage for media or solvent.
Protector Kit for External Temperature Sensor
The optional External Temperature Sensor, which checks the temperature of articles to be sterilized, is not fixed and hangs down inside of the chamber.
When you load and unload baskets containing the articles to be sterilized, the External Temperature Sensor may come in contact with the edge or wall surface of the basket, causing damage or disconnection.
The Protector Kit for External Temperature Sensor can fix the External Temperature Sensor on the chamber wall and protect it with a stainless steel pipe and a silicone tube to reduce the risk of damage or disconnection of the External Temperature Sensor. It also makes it easier to load and unload baskets.
Secure Sterilization
Fine Pressure Adjustment
Time-saving
Cooling Fan System
User-friendly Basket, Bucket and Long Basket
Long Basket
Full Package for Multiple Shared Use Autoclave SX-700
Multiple Shared Use
Autoclave SX-700
External Temperature Sensor
Optional Printer
(Thermal Paper Type)
Protector Kit for External Temperature Sensor